- Suitable for BPON,EPON,GPON
- Providing simultaneous measurement at all three wavelengths
- Used in burst mode measurement of 1310nm upstream
- VFL Function for quick and efficient Visual Inspection
- Optical Power Meter Module and VFL with one port
- 10 minutes Auto-off function can be activated or deactivated
- Auto-off function can be activated or deactivated
TF-2204 series’ Handheld PON Optical Power Meter is developed for FTTx FTTH application and maintenance. This power meter is able to simultaneously test and estimate the signals of the voice, data and video. It is an essential and ideal tool for the construction and maintenance of PON projects.
Applications:
- Telecom and HFC network
- Network installation and network maintenance
- CATV System
- FTTx FTTH Project
Specifications:
Parameter | Specification | |||||
PON Power Meter Module | ||||||
Model | TF-2204-A | TF-2204-B | TF-2204-C | TF-2204-D | ||
1310 Upstream Measurement | Pass Zone(nm) | 1260~1360 | ||||
Isolation@ 1490/1550 | >40 | |||||
Measurement Range(dBm) | -40~+10 | |||||
Max.Output Power(dBm) | 15 | |||||
Burst mode Measurement Error | <±0.5dB | |||||
1490 Downstream Measurement | Pass Zone(nm) | 1470~1505 | ||||
Isolation@ 1310/1550nm | >40 | |||||
Max.Output Power(dBm) | 15dBm | |||||
Measurement Range | -40~+10 | |||||
1550 Downstream Measurement | Pass Zone(nm) | 1535~1570 | ||||
Isolation @ 1310/1490nm | >40 | |||||
Max.Output Power(dBm) | 25dBm | |||||
Measurement Range | -40~+20 | |||||
Measurement Accuracy | Connatural Uncertainty (dB) | ±0.5 | ||||
Linearity(dB) | ±0.1 | |||||
Passing Through Insertion Loss(dB) | <1.5 | |||||
Measurement Unit(dBm) | dB, dBm, xW | |||||
Normal Optical Power Meter Module | ||||||
Model | TF-2204-A | TF-2204-B | TF-2204-C | TF-2204-D | ||
Calibration Wavelength(nm) | General Optical Power Meter Model is not available | 1300,1310, 1490,1550, 1625 | General Optical Power Meter Model is not available | 850,1300, 1310,1490, 1550,1625 | ||
Measurement Accuracy | Connatural Uncertainty (dB) | ±0.5 | ±0.5 | |||
Linearity(dB) | ±0.1 | ±0.1 | ||||
Passing Through Insertion Loss(dBm) | -70~+6 | -70~+6 | ||||
Measurement Unit (dBm) | dB, dBm | |||||
VFL Module | ||||||
Model | TF-2204-A | TF-2204-B | TF-2204-C | TF-2204-D | ||
Output Power | VFL module is not available | >0.5mW | VFL module is not available | |||
Wavelength (nm) | 650nm | |||||
Fiber Type | FC/SC/ST interchangeable; 2.5mm universal adapter | |||||
Optical Interface | SM and MM | |||||
General Specification | ||||||
Detector Type | InGaAs | |||||
Fiber Type | Single Mode Fiber, 9/125um | |||||
Optical Connector | FC(SC,ST interchangeable), 2.5mm universal | |||||
Display | LCD Screen, 128×64mm | |||||
Resolution(dB) | 0.01 | |||||
Power Adapter(V) | DC:3.3 ~ 5.5V | |||||
Alkaline Battery | 3*AA,1.5V | |||||
Continuously Operating Time(hrs) | PON Power Meter Mode: 90 h Normal Power Meter Mode:100h VFL Mode: 50h | |||||
Operation Temp.(℃) | -10 ~ +60 ℃ | |||||
Storage Temp.(℃) | -25 ~ +70 ℃ | |||||
Relative Humidity | 0 ~ 95 % (non-considering) | |||||
Weight(g) | 425g | |||||
Dimension(mm) | 192×102×50 |
Ordering Information:
Part No. | Name | Description |
TF-2204-A | PON Optical Power Meter | With PON Power Meter Module; Without General Power Meter Module Without VFL Module |
TF-2204-B | PON Optical Power Meter | With PON Power Meter Module; With General Power Meter Module With VFL Module |
TF-2204-C | PON Optical Power Meter | With PON Power Meter Module; Without General Power Meter Module With VFL Module |
TF2204-D | PON Optical Power Meter | With PON Power Meter Module; With General Power Meter Module Without VFL Module |
Standard Package:
Item | Name | Qty |
1 | PON Optical Power Meter | 1 PC |
2 | AC Power Adapter | 1 PC |
3 | 15V Battery | 3 PC |
4 | Cotton Swabs | 1 PC |
5 | User Manual | 1 PC |
6 | Soft Carrying Case | 1 PC |